ALSA: usb-audio: Remove VALIDATE_RATES quirk for Focusrite devices

Remove QUIRK_FLAG_VALIDATE_RATES for Focusrite. With the previous
commit, focusrite_valid_sample_rate() produces correct rate tables
without USB probing.

QUIRK_FLAG_VALIDATE_RATES sends SET_CUR requests for each rate (~25ms
each) and leaves the device at 192kHz. This is a problem because that
rate: 1) disables the internal mixer, so outputs are silent until an
application opens the PCM and sets a lower rate, and 2) the Air and
Safe modes get disabled.

Fixes: 5963e52621 ("ALSA: usb-audio: Enable rate validation for Scarlett devices")
Signed-off-by: Geoffrey D. Bennett <g@b4.vu>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
Link: https://patch.msgid.link/09b9c012024c998c4ca14bd876ef0dce0d0b6101.1771594828.git.g@b4.vu
This commit is contained in:
Geoffrey D. Bennett 2026-02-21 02:34:48 +10:30 committed by Takashi Iwai
parent 24d2d3c5f9
commit a8cc55bf81

View file

@ -2424,7 +2424,7 @@ static const struct usb_audio_quirk_flags_table quirk_flags_table[] = {
VENDOR_FLG(0x07fd, /* MOTU */
QUIRK_FLAG_VALIDATE_RATES),
VENDOR_FLG(0x1235, /* Focusrite Novation */
QUIRK_FLAG_VALIDATE_RATES),
0),
VENDOR_FLG(0x1511, /* AURALiC */
QUIRK_FLAG_DSD_RAW),
VENDOR_FLG(0x152a, /* Thesycon devices */